TWO-WAY VALVE POLYCARBONATE SILICONE TRANSPARENT FLUSH NEUTRAL

Reference : VALBDDN02

  • Sterile
  • Female luer lock/male luer lock connection
  • Flush Neutral

Description

Patented design: Bidirectional valve allowing the administration of medications and/or the collection of blood derivatives, maintenance of asepsis by automatic closure, no risk of needlestick or contamination for the patient or caregiver, ergonomics (direct access without cap).

In all cases, the valve septum must be disinfected before each connection with another DM.
Reliable and secure: System with double seal, no metal components (MRI compatible)
Lipid resistant
Compatibility: Possible use of antiseptic based on 70° alcohol (avoid 2% chlorhexidine solutions in isopropyl alcohol because of the risk of cracking of the valve body).

Neutral Flush: Maximum negative displacement: 0.008 mL
Usage Time: The usage time must not exceed 72 hours on a central channel and 96 hours on a peripheral channel or 200 activations.

Pressure: 4140 hPa / 4.14 Bars / 60 psi

Flow rate: 100mL/min - 6L/h

Residual volume: 0.044mL

Activation volume: 0.035 mL

Connection: LL female/LL male

Technical
information

Indications 
This product is intended to inject or collect liquids without needles.

Used materials 
Body: ABS / Polyprolylene Valve: Silicone

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 0197
  • EU directive/regulation : DIRECTIVE 93/42/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications

Logistics
information

Transport conditions 

Protected from light and humidity

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 06972620110411
BOX 100 11 x 21 x 10 16972620110418
CASE 600 23 x 35 x 23 26972620110415

Patented design: Bidirectional valve allowing the administration of medications and/or the collection of blood derivatives, maintenance of asepsis by automatic closure, no risk of needlestick or contamination for the patient or caregiver, ergonomics (direct access without cap).

In all cases, the valve septum must be disinfected before each connection with another DM.
Reliable and secure: System with double seal, no metal components (MRI compatible)
Lipid resistant
Compatibility: Possible use of antiseptic based on 70° alcohol (avoid 2% chlorhexidine solutions in isopropyl alcohol because of the risk of cracking of the valve body).

Neutral Flush: Maximum negative displacement: 0.008 mL
Usage Time: The usage time must not exceed 72 hours on a central channel and 96 hours on a peripheral channel or 200 activations.

Pressure: 4140 hPa / 4.14 Bars / 60 psi

Flow rate: 100mL/min - 6L/h

Residual volume: 0.044mL

Activation volume: 0.035 mL

Connection: LL female/LL male

Indications 
This product is intended to inject or collect liquids without needles.

Used materials 
Body: ABS / Polyprolylene Valve: Silicone

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 0197
  • EU directive/regulation : DIRECTIVE 93/42/CEE
  • annexe : V

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Small-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular or hypodermic applications

Transport conditions 

Protected from light and humidity

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 06972620110411
BOX 100 11 x 21 x 10 16972620110418
CASE 600 23 x 35 x 23 26972620110415

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.