PVC INFUSION KIT WITHOUT DEHP FLAT FILTER 0.2µ GRAVITY 5.5

Reference : PER1FLFP02

  • Bisphenol A and DEHP free (<0.1% m/m.)
  • Designed to minimise the environmental footprint by reducing the weight of plastic materials.
  • 0.2µm filter with very low polyethersulfone protein binding.

Description

The INFINEED 1-way infusion device "Gravity 5.5" sterile, DEHP free, BPA free has been designed to minimise its environmental impact, using only raw materials that are free from endocrine disruptors (elimination of components, including DEHP or BPA).

Infuser with:

Perforator: Two-channel with grip wings

Air intake: Delivered closed for immediate use on a 0.2µ filter bag.

Chamber:  Flexible and transparent, Calibrated at 20 drops = 1ml ± 0.1ml, 15µ particle filter.

Flow regulator: Accurate and reliable, linear flow regulator.

Filter: 0.2µm flat filter with very low polyethersulfone protein binding (can be used with taxanes, etoposide, monoclonal antibodies in oncology).

Tubing: PVC (DINCH) designed for comfort, optimal flow adjustment consistency and to prevent kinks.

End fitting: Mobile Luer Lock.

End stopper: 0.8 µm purge filter with antibacterial membrane.

Length: 150 cm + 30 cm
Residual volume: 16.5 ml

Technical
information

Indications 
This device enables the parenteral administration by gravity of injectable preparations: parenteral drugs, solutions and nutrition, requiring administration filtered at 0.2 µm (can be used with taxanes, etoposide, monoclonal antibodies in oncology). For peripheral lines, the infusion line can remain in place for a maximum of 96 hours (i.e. the maximum time the peripheral catheter can be in place). For central lines, the infusion line must be changed at least every 72 hours (or according to the institution's validated protocol).

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
  • Infusion equipment for medical use - Part 4 : Infusion sets for single use, gravity feed.

Logistics
information
Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 0.040 3661809032769
BOX 75 27 x 39 x 29 3.160 3661809032776
CASE 300 57 x 60 x 40 13.400 3661809032783

The INFINEED 1-way infusion device "Gravity 5.5" sterile, DEHP free, BPA free has been designed to minimise its environmental impact, using only raw materials that are free from endocrine disruptors (elimination of components, including DEHP or BPA).

Infuser with:

Perforator: Two-channel with grip wings

Air intake: Delivered closed for immediate use on a 0.2µ filter bag.

Chamber:  Flexible and transparent, Calibrated at 20 drops = 1ml ± 0.1ml, 15µ particle filter.

Flow regulator: Accurate and reliable, linear flow regulator.

Filter: 0.2µm flat filter with very low polyethersulfone protein binding (can be used with taxanes, etoposide, monoclonal antibodies in oncology).

Tubing: PVC (DINCH) designed for comfort, optimal flow adjustment consistency and to prevent kinks.

End fitting: Mobile Luer Lock.

End stopper: 0.8 µm purge filter with antibacterial membrane.

Length: 150 cm + 30 cm
Residual volume: 16.5 ml

Indications 
This device enables the parenteral administration by gravity of injectable preparations: parenteral drugs, solutions and nutrition, requiring administration filtered at 0.2 µm (can be used with taxanes, etoposide, monoclonal antibodies in oncology). For peripheral lines, the infusion line can remain in place for a maximum of 96 hours (i.e. the maximum time the peripheral catheter can be in place). For central lines, the infusion line must be changed at least every 72 hours (or according to the institution's validated protocol).

Labeling 
on each unit are written the reference, the lot/serial number, the sterilization method and the expiry date if applicable

medical device 

  • MD class : IIa
  • MD notified body : 1370
  • EU directive/regulation : 93/42/CEE - 2007/47/CEE
  • annexe : II

sterile 

  • sterile : yes
  • sterilization method : ethylene oxide

conformity 

  • Sterilization of health-care products - Ethylene oxide - Requiremnets for the development, validation and routine control of a sterilization process for medical devices
  • Biological evaluation of medical devices - Part 7: Ethylene oxide sterilization residuals
  • Medical devices - Symbols to be used with medical device labels, labelling and information to be supplied - Part 1: General requirements
  • Infusion equipment for medical use - Part 4 : Infusion sets for single use, gravity feed.

Conditioning Parts quantities Dimensions in cm Weight in kg Ean 13 of conditioning
UNIT 1 0.040 3661809032769
BOX 75 27 x 39 x 29 3.160 3661809032776
CASE 300 57 x 60 x 40 13.400 3661809032783

Request for technical documentation

  • Didactic formally undertakes not to sell, rent or exchange any personal information. In application of articles 39 and following of the law of January 6, 1978 modified relating to data processing and freedoms (CNIL), you have the right to access, delete and rectify information concerning related to you.